1. |
Turn power off, unplug the unit. |
 |
2. |
Open control panel. |
| 3. |
Check switch to be replaced, loosen the terminals and remove wiring.
Note: When disconnecting wires, write down wire numbers and positions. |
 |
4. |
Remove the over current relay (OCR) section.
Note: Motor contactors use over current relays, heaters do not. |
 |
5. |
Remove it by unscrewing the upper terminals from the contactor above.
Locate the release tab the contactor and push down to release it. |
 |
6. |
While pulling down, pull forward, then remove relay by holding upward. |
| 7. |
Install new relays. (Contrary to #6 above, hook top section to rails, then fit bottom section by pushing this onto rails) |
| 8. |
Re-wire
(Securely tighten all wires. If loose, terminals may burn due to heat) |
 |
9. |
Check / confirm set value of over current relay, turn dial to specified current |
| |
*The thermal set value every equipment refer to the following.
Thermal set value |