Issues
 
Will guide user from causes of trouble to troubleshooting.

What types of problem do you need help with? Please select from the list below.
[Issues]
  • Blower does not rotate.
  • Blower is overloaded and the thermal relay trips.
  • Low Air Flow from Blower.
  • Drying temperature is erratic.
  • Drying temperature does not go up and down.
  • Power breaker trips.
[Errors]
  • E0 EPROM Error
  • E1 Reverse Phase
  • E2 Dry Blower Overload
  • E3 Convey Blower Overload
  • E4 Upper Limit Temperature Alarm
  • E5 Drying Heater Alarm
  • E6 Regenerate Heater Alarm
  • E7 Primary (1st) Convey Alarm
  • E8 Feed - No. 1 Convey Alarm (same measures apply to E9 ~ E15)
  • E17 Overheat Alarm
  • E18 Lower Limit Temperature Alarm
[Replacement/Adjustment]
  • Filter Cleaning
  • Motor Heater Damage Inspections
  • SSR (Solid State Relay) Inspections
  • Electromagnetic Switch
  • Optical Sensor Adjustment
  • Level Meter Sensitivity Adjustments

NOTE
  • Before starting work, please press the operation switch to stop operations. Once confirming that the unit has completely stopped, turn off the primary source of power from your company's electrical supply equipment. After this, bring temperature of unit down to the point where worker will not suffer any burn-related injuries.
    Also, for instructions on how to remove the filters, see the Maintenance section.
  • Maintenance checks should be made by authorized personnel only.
    For parts installments, please have Matsui service workers or qualified, authorized personnel do the work.