| No. |
CODE |
SETTING ITEMS |
SETTINGS |
SET RANGE |
INITIAL VALUE |
| 1 |
Fd1 |
No. 1 Conveyance Timer |
Will set conveying time of No. 1 directionTimes will vary by conveying distance, types of material and collection hopper.
Conveying will be set to conclude before
hopper becomes full
|
0~999sec. |
5sec. |
| 2 |
Fd2 |
No. 1 Conveyance Timer |
Will set conveying time of No. 2 directionTimes will vary by conveying distance, types of material and collection hopper.
Conveying will be set to conclude before hopper becomes full
|
same as above |
same as above |
| 3 |
dC1 |
No. 1 Discharge Timer |
Will set discharge time of No. 1 collection hopper.
Times will vary by type of material, size of hopper
and set-up of discharge Hopper will be set to completely discharge material
|
0~999sec. |
20sec. |
| 4 |
dC2 |
No. 1 Discharge Timer |
Will set discharge time of No. 2 collection hopper.
Times will vary by type of material,
size of hopper and set-up of discharge Hopper will be set to completely dischargematerial
|
same as above |
same as above |
| 5 |
dUC |
Dust Cleaning Counter |
Will be set to indicate notice of filter cleaning time based on number of
conveyance.
Will not work when turned oFF.
When conveyance cycle reaches the set value, digital board of operation panel
will indicate "E15" and notify when it is time to clean.
Setting cycle will depend on type of material and how it is used.
|
oFF,
1~999times
|
oFF |
| 6 |
dUP |
Dust Cleaning Count |
Will display actual count number of the dust cleaning counter (active).The count number is reset when set to 0.
|
0~999times |
0 |