Limit Switch Adjustments

[Condition]
If cam position is poor, convey problems will happen due to "no convey signal" or "no full capacity signal."
[Adjustment]
  1. Remove any material in contact with damper. Set in free condition.
  2. Loosen set screw with hex socket wrench. From position where damper hangs down naturally (cam slightly rotated to the left), adjust cam to make limit switch turn on at slightly open position. Then secure by tightening set screw.