| 1. Controller light indicator does not light up. |
|
 |
 |
- Primary power may not be on, or STANDBY switch may not be pressed.
- Circuit Protector in control panel (CP-1) may not be turned on.
|
 |
- Turn primary power and power breaker (in front of controller) on and press STANDBY switch.

- Turn CP-1 on.

|

|
|
 |
|
|
 |
 |
| 2. Controller "Feeder" does not light up. |
|
 |
 |
| To start, press each "Feeder" switch. |
 |
 |
- If indicator does not light up, press "Feeder" switch.

|

|
|
 |
|
|
 |
 |
| 3. Weld damage/wear on contact point of electromagnetic switch in the control panel. |
|
 |
 |
| Electromagnetic switch will not function if abnormality is found. |
 |
 |
 |
Start work after stopping the operation and check that breaker is off. Unplug the unit. Those who do not have sufficient mechanical/electrical knowledge should not attempt any maintenance work requiring disassembly or repairing due to risk of injuries and danger of work. |
|
- Check to find any weld damages and wear on contact points, as well as any abnormalities.

[Point] After checking, securely set white cover back on.
Reference: Tolerance - 2 million times
| [Abnormal Function] |
| |
Condition where the magnetic points are damaged and center section is stuck closed, while the machine is idle, or does not unlock even when pressing by hand.
|
| |
 |
Start work after stopping the operation and check that breaker is off. Unplug the unit. Those who do not have sufficient mechanical/electrical knowledge should not attempt any maintenance work requiring disassembly or repairing due to risk of injuries and danger of work. |
|
- Replace the switch if weld damage or wear is found, or when the function is abnormal.
|

Electromagnetic Switch Replacement 
If problem persists 
|
|
 |
|
|
 |
 |
| 4. Error code "E3" is displayed on the controller (Blower Overload). |
|
 |
 |
Error will occur when overload current runs in blower and overload relay to switch trips.
Reference - Operation will automatically stop. |
 |
 |
- Check to see if the electromagnetic switch is thermally tripped.

*Click here for overload causes
- After repairing overload in the blower, press the reset button on overload relay.
After eliminating cause of overload, the alarm code will not appear after pressing RESET.
|

|
|
 |
|
|
 |
| 5. Conveying Jet Clone limit switch is ON despite low material. |
|