| 1. Drying heater is disconnected. |
|
 |
 |
| If disconnected, temperature will not rise. |
 |
- Check to see if Drying Heater is disconnected or if terminal is loosened.
|
|
 |
|
|
 |
 |
 |
| 2. Connecting hoses in dehumidifying unit and the one between dehumidifying unit and dryer hopper is damaged or connection is loose. |
|
 |
 |
 |
|
- Check to see if any section is damaged or loosened.

|
|
 |
|
|
 |
 |
| 3. Check cooling water flow or if water volume is lacking or not (MJ3-100 ~ 300) |
|
 |
 |
| When cooling water is not running, drying dew point will not drop, causing drying defects or affecting drying temperature. |
 |
|
- If cooling water is not running, check all valves are open.
[Point]
Set pressure of cooling water inlet below 0.49 MPa / 71 P.S.I.
|
|
 |
|
|