Will set time to judge No. 1 Demand signal.
Will also be set to ignore a false demand signal, such as short times when material is flowing
0~99sec.
5sec.
2
1Ed
No. 1 Conveyance
Error Timer
Will set level switch "Demand Status Monitor Time" while No. 1 conveyor is operating
oFF,
1~999sec.
oFF
3
2Ed
No. 2 Conveyance
Error Timer
Will set level switch "Demand Status Monitor Time" while No. 2 conveyor is operating
oFF,
1~999sec.
oFF
4
L2d
No. 2 Demand
Signal Delay Timer
Will set time to judge No. 2 Demand signal. Will also be set to ignore a false demand signal, such as short times when material is flowing
Same as above
Same as above
5
1rL
No. 1 Demand
Signal Input Timer
Will set type of No. 1 Demand Signal.
no: Demand signal when input circuit is open
nC: Demand signal when input circuit is closed
nC/no
no
6
2rL
No. 2 Demand
Signal Input Timer
Will set type of No. 2 Demand Signal.
same as above.
Same as above
Same as above
7
bt1
No. 1 Batch Gate
Timer
Will set opening time of the auto-slide damper at No. 1 direction.
Will set to convey at preferred amount
0.0~
99.9sec.
1.0
8
bt2
No. 2 Batch Gate
Timer
Will set opening time of the auto-slide damper at No. 2 direction.
same as above.
Same as above
Same as above
9
bn_
Batch Gate
Interlock Direction
Will be set for interlocking the conveying direction when batch conveying is performed.
oFF: No batch conveying
1: Interlocking toward No. 1 direction
2: Interlocking toward No. 2 direction
ALL: Interlocking at both directions
oFF,1,2, ALL
oFF
10
bS_
Batch Gate
Will changeover types when running the optional batch conveying.
0: Auto-slide Gate
1 ~ 2: Unable to set with standard specifications or with optional use. Can only be set with special specifications.
Notes:
1: Idling Valve
2: MSD
0
0
11
Jd_
---
Set in case of special specifications. Keep initial values