NAME |
Characters |
Setting Range |
Initial Setting |
Special Notes |
---|
Primary Convey |
PEn | on/oFF | on |
--- |
Feed-No.1 |
1En | on/oFF | on | --- |
Feed-No.2 |
2En | on/oFF | on | --- |
Feed-No.3 *2 |
3En | on/oFF | on | --- |
Feed-No.4 *2 |
4En | on/oFF | on | --- |
Feed-No.5 *2 |
5En | on/oFF | on | --- |
Feed-No.6 *2 |
6En | on/oFF | on | --- |
Feed-No.7 *2 |
7En | on/oFF | on | --- |
Feed-No.8 *2 |
8En | on/oFF | on | --- |
Upper Limit Temperature Alarm Detect Delay Time |
ULt |
0~999sec, |
5sec. |
--- |
Primary Convey Abnormal Detect Count |
LCt |
0~999times |
50times |
Stop at "0" |
Dryer Level Meter Abnormal Detect Count |
FCt |
0~999times |
20times | Stop at "0" |
Primary Convey Abnormal Detect Delay Time Feed - No. 1 Convey Abnormal Detect Delay Time *1 |
PEd |
0~999min. |
120min. | Stop at "0" |
Feed-No.1Convey Abnormal Detect Delay Time *1 |
1Ed |
0~999sec. |
180sec. | Stop at "0" |
Feed-No.2Convey Abnormal Detect Delay Time *1 |
2Ed |
0~999sec. |
180sec. | Stop at "0" |
Feed-No.3Convey Abnormal Detect Delay Time *1,*2 |
3Ed |
0~999sec. |
180sec. | Stop at "0" |
Feed-No.4Convey Abnormal Detect Delay Time *1,*2 |
4Ed |
0~999sec. |
180sec. | Stop at "0" |
Feed-No.5Convey Abnormal Detect Delay Time *1,*2 |
5Ed |
0~999sec. |
180sec. | Stop at "0" |
Feed-No.6Convey Abnormal Detect Delay Time *1,*2 |
6Ed |
0~999sec. |
180sec. | Stop at "0" |
Feed-No.7Convey Abnormal Detect Delay Time *1,*2 |
7Ed |
0~999sec. |
180sec. | Stop at "0" |
Feed-No.8Convey Abnormal Detect Delay Time *1,*2 |
8Ed |
0~999sec. |
180sec. | Stop at "0" |
Drying Temperature Upper Limit Difference |
dUS | 0~40 degrees C | 10 degrees C | Stop at "0" |
Regenerate Temperature Upper Limit Difference |
rUS | 0~40 degrees C | 10 degrees C | Stop at "0" |
Drying -side Disconnect Delay Time |
dLP |
0~999min. |
0min. | Stop at "0" |
Regenerate -side Disconnect Delay Time |
rLP |
0~999min. |
0min. | Stop at "0" |
Primary Convey Level Meter Demand Delay *1 |
LPd |
0~999sec. |
15sec. |
--- |
Feed-No.1Level Meter Demand Delay *1 |
L1d |
0~999sec. |
15sec. |
--- |
Feed-No.2Level Meter Demand Delay *1 |
L2d |
0~999sec. |
15sec. |
--- |
Feed-No.3Level Meter Demand Delay *1,*2 |
L3d |
0~999sec. |
15sec. |
--- |
Feed-No.4Level Meter Demand Delay *1,*2 |
L4d |
0~999sec. |
15sec. |
--- |
Feed-No.5Level Meter Demand Delay *1,*2 |
L5d |
0~999sec. |
15sec. |
--- |
Feed-No.6Level Meter Demand Delay *1,*2 |
L6d |
0~999sec. |
15sec. |
--- |
Feed-No.7Level Meter Demand Delay *1,*2 |
L7d |
0~999sec. |
15sec. |
--- |
Feed-No.8Level Meter Demand Delay *1,*2 |
L8d |
0~999sec. |
15sec. |
--- |
Reverse/Missing Phase Detect |
rSt | 0~1 | 1 | Stop at "0" |
Primary Convey Exhaust Valve Bite Prevention Cycle |
PEr |
oFF,1~10times |
off |
Stop at "oFF" |
Primary Convey Exhaust Valve Bite Prevention Open Time |
PEo |
1~10sec. |
2sec. |
--- |
Primary Convey Exhaust Valve Bite Prevention Close Time |
PEC |
1~10sec. |
2sec. |
--- |
Secondary Convey Exhaust Valve Bite Prevention Cycle |
SEr |
oFF,1~10times |
off |
Stop at "oFF" |
Secondary Convey Exhaust Valve Bite Prevention Open Time |
SEo |
1~10sec. |
2sec. |
--- |
Secondary Convey Exhaust Valve Bite Prevention Close Time |
SEC |
1~10sec. |
2sec. |
--- |
Exhaust Valve - Pre-Release Open Time |
Pdt |
oFF,1~10sec. |
off | Stop at "oFF" |
Convey Blower Start - Delay Time |
PdH(PdW) |
1~10sec. |
1sec. |
--- |
Tank - Empty Detect Delay |
?et(MEt) |
oFF,0~99sec. |
60sec. | Stop at "oFF" |
Drying Temperature Lower Limit Difference |
dLS | 0~40 degrees C
or
0~72 degrees F | 10 degrees C
or
18 degrees F | Stop at "0" |
Regenerate Temperature Lower Limit Difference |
rLS | 0~40 degrees C
or
0~72 degrees F | 10 degrees C
or
18 degrees F | Stop at "0" |