DMD4 - Engineering Setting Mode Parameters

Control Panel will switch to Engineering Setting Mode if SV switch is held for more than 5 seconds.
After this, character displays will change every time the SV switch is pressed.
NAME Characters Setting Range Initial Setting Special Notes
Primary Convey
PEnon/oFFon ---
Feed-No.1
1Enon/oFFon---
Feed-No.2
2Enon/oFFon---
Feed-No.3 *2
3Enon/oFFon---
Feed-No.4 *2
4Enon/oFFon---
Feed-No.5 *2
5Enon/oFFon---
Feed-No.6 *2
6Enon/oFFon---
Feed-No.7 *2
7Enon/oFFon---
Feed-No.8 *2
8Enon/oFFon---
Upper Limit Temperature Alarm Detect Delay Time
ULt 0~999sec, 5sec. ---
Primary Convey Abnormal Detect Count
LCt 0~999times 50times Stop at "0"
Dryer Level Meter Abnormal Detect Count
FCt 0~999times 20timesStop at "0"
Primary Convey Abnormal Detect Delay Time Feed - No. 1 Convey Abnormal Detect Delay Time *1
PEd 0~999min. 120min.Stop at "0"
Feed-No.1Convey Abnormal Detect Delay Time *1
1Ed 0~999sec. 180sec.Stop at "0"
Feed-No.2Convey Abnormal Detect Delay Time *1
2Ed 0~999sec. 180sec.Stop at "0"
Feed-No.3Convey Abnormal Detect Delay Time *1,*2
3Ed 0~999sec. 180sec.Stop at "0"
Feed-No.4Convey Abnormal Detect Delay Time *1,*2
4Ed 0~999sec. 180sec.Stop at "0"
Feed-No.5Convey Abnormal Detect Delay Time *1,*2
5Ed 0~999sec. 180sec.Stop at "0"
Feed-No.6Convey Abnormal Detect Delay Time *1,*2
6Ed 0~999sec. 180sec.Stop at "0"
Feed-No.7Convey Abnormal Detect Delay Time *1,*2
7Ed 0~999sec. 180sec.Stop at "0"
Feed-No.8Convey Abnormal Detect Delay Time *1,*2
8Ed 0~999sec. 180sec.Stop at "0"
Drying Temperature Upper Limit Difference
dUS0~40 degrees C10 degrees CStop at "0"
Regenerate Temperature Upper Limit Difference
rUS0~40 degrees C10 degrees CStop at "0"
Drying -side Disconnect Delay Time
dLP 0~999min. 0min.Stop at "0"
Regenerate -side Disconnect Delay Time
rLP 0~999min. 0min.Stop at "0"
Primary Convey Level Meter Demand Delay *1
LPd 0~999sec. 15sec. ---
Feed-No.1Level Meter Demand Delay *1
L1d 0~999sec. 15sec. ---
Feed-No.2Level Meter Demand Delay *1
L2d 0~999sec. 15sec. ---
Feed-No.3Level Meter Demand Delay *1,*2
L3d 0~999sec. 15sec. ---
Feed-No.4Level Meter Demand Delay *1,*2
L4d 0~999sec. 15sec. ---
Feed-No.5Level Meter Demand Delay *1,*2
L5d 0~999sec. 15sec. ---
Feed-No.6Level Meter Demand Delay *1,*2
L6d 0~999sec. 15sec. ---
Feed-No.7Level Meter Demand Delay *1,*2
L7d 0~999sec. 15sec. ---
Feed-No.8Level Meter Demand Delay *1,*2
L8d 0~999sec. 15sec. ---
Reverse/Missing Phase Detect
rSt0~11Stop at "0"
Primary Convey Exhaust Valve Bite Prevention Cycle
PEr oFF,1~10times off Stop at "oFF"
Primary Convey Exhaust Valve Bite Prevention Open Time
PEo 1~10sec. 2sec. ---
Primary Convey Exhaust Valve Bite Prevention Close Time
PEC 1~10sec. 2sec. ---
Secondary Convey Exhaust Valve Bite Prevention Cycle
SEr oFF,1~10times off Stop at "oFF"
Secondary Convey Exhaust Valve Bite Prevention Open Time
SEo 1~10sec. 2sec. ---
Secondary Convey Exhaust Valve Bite Prevention Close Time
SEC 1~10sec. 2sec. ---
Exhaust Valve - Pre-Release Open Time
Pdt oFF,1~10sec. offStop at "oFF"
Convey Blower Start - Delay Time
PdH(PdW) 1~10sec. 1sec. ---
Tank - Empty Detect Delay
?et(MEt) oFF,0~99sec. 60sec.Stop at "oFF"
Drying Temperature Lower Limit Difference
dLS0~40 degrees C
or
0~72 degrees F
10 degrees C
or
18 degrees F
Stop at "0"
Regenerate Temperature Lower Limit Difference
rLS0~40 degrees C
or
0~72 degrees F
10 degrees C
or
18 degrees F
Stop at "0"