GMC Mold Temperature Controller  
Issues > Check/Troubleshooting
Temperature Controller Control Panel does not light up.
  1. Power breaker is not on.
  2. Glass tube fuse is blown.

1. Power breaker is not on.
  1. Check to see if power breaker is on.
If unit turns off immediately
If problem persists
Return to top of the page
2. Glass tube fuse is blown.
Please have authorized worker perform inspections. For parts replacements, do not have anyone besides authorized workers or a Matsui service worker perform the work.
  1. Open control panel and see if fuse is blown or not.
  2. The fuse type is 250V-2A (Φ 6.4 x L30mm). If fuse gets blown again, it is a short circuit. Please contact your local Matsui service offices.
If problem persists
Return to top of the page


Scroll to Top